Operating Instructions
SKC Deployable Cartridge
Sampler (DCS) System
SKC Inc.
863 Valley View Road
Eighty Four, PA 15330
Form #38048 Rev 1008
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - Sampler (DCS) System

Operating InstructionsSKC Deployable Cartridge Sampler (DCS) SystemSKC Inc.863 Valley View RoadEighty Four, PA 15330Form #38048 Rev 1008

Page 2 - DCS System Quick Guide

7SAMPLE PUMP OPERATIONThe user may choose to: • Operate the pump manually in the fi eld (on/off )• Program a schedule into the pump manually• Program

Page 3 - Table of Contents

8ba ery from charger and connect pump to ba ery (see Ba ery Setup below).A er charging the ba ery pack, it is good practice to run the pump for a

Page 4 - INTRODUCTION

9Leland Legacy Quick GuideTerms »Star button Ò• Scrolls through run time data and Setup optionsUp and down arrow buttons ST• Toggle between display

Page 5 - PERFORMANCE PROFILE

10CALIBRATION AND SAMPLINGCalibrationCalibrate pump fl ow rate with the sampling head loaded with a cartridge in line. See pump and calibrator operatin

Page 6 - PRINCIPLE OF OPERATION

11SamplingLocate system in an unobstructed area, at least 6 feet (2 meters) from any obstacle to airfl ow.Wear disposable, clean, lint-free nylon or po

Page 7 - CARTRIDGE PREPARATION

12SAMPLE REMOVAL, SHIPPING, AND ANALYSISRemoving the Cartridge from the Sampling HeadWear disposable, clean, lint-free nylon or powder-free surgical g

Page 8 - SAMPLING HEAD PREPARATION

13Removing Filter and Sorbent from CartridgeFor Laboratory Use Only1. Remove fi lter and sorbent(s) from cartridge.2. Combine for extraction.3. a. F

Page 9

14ORDERING INFORMATIONDescription Cat. No.DCS System†# includes a Leland Legacy Sample Pump with connection case and cable, charger (100-240 V), 2 ext

Page 10 - SAMPLE PUMP OPERATION

15LI-ION BATTERY SHIPMENTRechargeable lithium-ion ba eries for use with SKC sample pumps have been tested in accordance with the UN Manual and are pr

Page 11 - Battery Replacement

Pre3DCS System Quick GuideSampling Head and Cartridge Installation1. Disassemble sampling head: Unscrew inlet from cartridge holder section. Unscrew

Page 12 - Leland Legacy Quick Guide

Pre5Table of ContentsIntroduction ...1Performance Profi le ...

Page 13 - CALIBRATION AND SAMPLING

1INTRODUCTIONThe SKC Deployable Cartridge Sampler (DCS) System is a compact, portable, and ba ery-operated sampling system that ensures the ability t

Page 14 - Sampling

2PERFORMANCE PROFILEFlow Rate: 10 L/minRun Time: > 24 hrs on one battery chargePower: Rechargeable lithium-ion (Li-Ion) battery, 7.4 V, 12-Ah cap

Page 15 - ANALYSIS

3PRINCIPLE OF OPERATIONA sample pump draws air at a fl ow rate of 10 L/min through nozzles on top of the sampling head and into the cartridge. The cart

Page 16 - Analysis

4MEDIA PREPARATIONFor Laboratory UseUse clean hexane-rinsed PTFE-tipped forceps to handle fi lters.Wear disposable, clean, lint-free nylon or powder-fr

Page 17 - ORDERING INFORMATION

5Deployment of Cartridges for Field SamplingImmediately prior to fi eld deployment, follow the procedure in EPA TO-9A or TO-13A, Section 10.4.SAMPLING

Page 18 - LI-ION BATTERY SHIPMENT

6Inserting a Cartridge into the Sampling HeadWear disposable, clean, lint-free nylon or powder-free surgical gloves to handle the sorbent and cartridg