Operating InstructionsSKC Inc.863 Valley View RoadEighty Four, PA 15330 USAForm 37740 Rev 1302
7Battery Operation2. Carefully align the ba ery jack on the replacement ba ery pack with the ba ery terminal on the bo om of the pump base plate
8Pump DisplayHOLD: Flashes when the pump is in HOLD mode (see page 10)SГ or S: Displayed when a sample time is manually programmed into pump memory
9Keypad BasicsThe AirChek 2000 Pump operates by pressing various bu on sequences on the keypad located on the front of the pump housing. Scrolls
10Pump Operating ModesRUN Pump is running; run time data is continuously updated in memory. The LCD shows real-time run time data. Press to scroll t
11Verifying Battery Charge LevelThe LCD displays an icon that shows the current ba ery charge level (see Ba ery Operation on page 5). A new ba ery
12ADJ Used during calibration with primary standard calibrator (not for use with CalChek feature). Press to increase or to decrease fl ow adjustme
13Time of day The hour will fl ash. Press to increase and to decrease hour. Press to advance to minutes. Once minutes are fl ashing, press to i
14Setting Sample Time (S Г)Program the AirChek 2000 from the keypad to run STEL, TWA, or any other run time from 1 to 999 minutes*. AirChek 2000 sampl
15Setting a Delayed StartThe Delayed Start feature is available in pump version 2.59 or higher.When se ing the pump manually for sampling to begin wi
16Deleting a Sample Time (SГ)To delete a sample time, enter User Interface Level Two and press the bu on to scroll to SГ. Press until SГ 00 appea
Description ...
17Flow Rate and Volume DisplayFlow rate displayed on the pump LCD is the fl ow to which the pump has been calibrated. To maintain fl ow as displayed, th
189. Press until End appears on the LCD. Press [] to save fl ow se ing and exit the User Interface. The pump will remain in RUN. Reset run time d
19Calibration Using the CalChek Automatic Calibration FeatureThe CalChek automatic calibration feature is available when calibrating an AirChek 2000 P
20Calibration7. Place the pump in HOLD by pressing []. Press [] again to start the pump running, and enter the security code in sequence on
21CalibrationFull (Multiple-point) Calibration Using CalChekThis type of calibration provides fl ow correction across the basic operating range of the
22CalibrationCalChek Full Calibration DataFull calibration data can be viewed and printed by going to the DataTrac 2000 Pump Manager window and clicki
23CalibrationCalChek Error ChartSingle-point Calibration ErrorsError Problem TroubleshootingE41 Correction required too large. A mismatch of greater t
24Calibrating for Low Flow (5 to 500 ml/min) Sampling Applications Using a Constant Pressure Controller (CPC)For use with CPC and Adjustable Low Flow
25Sampling (1000 to 3250 ml/min Constant Flow)1. Following calibration, replace representative sampling medium with a new unexposed medium. Ensure r
26Low Flow Sampling (5 to 500 ml/min Constant Pressure)Low fl ow sampling requires a Constant Pressure Controller (CPC) and adjustable fl ow tube holder
Security Code Must be pressed within 10 seconds of previous commandMode ChangePress [] to toggle between Run and Hold.AirChek 2000 Quick GuideOp
27MaintenanceReplacing the Inlet Port Housing and Filter1. Remove the three screws that secure the inlet port housing to the top of the pump.2. Re
28This page is intentionally blank.
29Description Cat. No.Replacement Parts Ba ery Pack, NiCad P20136 Ba ery Pack, NiMH P20136MH Belt Clip P20139 Case P20137 Case with i
30Description Cat. No.Defender Primary Standard Calibrator, 50 to 5000 ml/min,includes ba ery, charger (100-240 V), so ware, and serial cable 717
31DataTrac 2000 SoftwareWith the optional DataTrac 2000 So ware accessory, the AirChek 2000 is programmable using a PC. DataTrac 2000 simplifi es chai
32SKC Limited Warranty and Return PolicySKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s sole liability an
33IndexAC Charger ...5, 30Accessories ...30Activate Pump ...
1The SKC AirChek® 2000 Pump is an advanced programmable sample pump that combines lightweight compact design, computer-compatible circuitry, and a pat
2Performance Profi leFlow Range: 1000 to 3250 ml/min (5 to 500 ml/min requires optional low fl ow adapter kit)Compensation Range: 3000 ml/min at 15
3Performance Profi leTime Display: Time of day in hours and minutes (12 or 24-hour clock) with AM and PM indicators Volume Display: Continually
4Table 1. AirChek 2000 Run Time in Hours with NiCad BatteryFollowing are typical run times achieved when using a fully charged nickel-cadmium (NiCad)
5Installing the Battery Pack1. Carefully align the ba ery jack on the ba ery pack with the ba ery ter-minal on the bo om of the pump base plate a
6Battery Charge Level IndicatorThree bars indicate a full charge (normally appears a er charging),approximately 75 to 100%. Two bars indicate that th